Acoustics
How to Select Acoustic Panels and Where to Place Them?
Acoustic panel types, thickness, air gaps, NRC and αw — how to select absorption, plan placement, and evaluate installation results.
An acoustic panel is an element used to change the sound reflection and absorption conditions in a room. The purpose of sound-absorbing panels is to reduce excessive reverberation, improve speech intelligibility, and create a more comfortable listening environment.
When selecting a panel, its acoustic characteristics, mounting construction, and the purpose of the room are important. Visually similar panels can differ significantly at various frequencies.
How a Panel Absorbs Sound
When a sound wave strikes a surface, it is partially reflected, partially absorbed, and partially transmitted through the construction.
In a porous absorber, the movement of air within the material loses energy, part of which is converted into a small amount of heat. Such materials include mineral wool, glass fiber, appropriate acoustic foam, and some fibrous polyesters.
USG's Acoustic Principles explain the difference between porous absorbers and sound-reflecting hard surfaces.
Not all soft materials are effective acoustic absorbers. Results should be evaluated by test data and not just by touch or appearance.
Main Types of Panels
| Type | Operational Feature |
|---|---|
| Fabric-covered porous panel | Sound passes through the appropriate cover and loses energy in the internal absorbent material |
| Fibrous polyester panel | Absorption depends on the material's structure, thickness, and mounting |
| Perforated or grooved panel | Openings, rear cavity, and additional materials create a unified acoustic system |
| Wooden slat system | The result is determined by the spacing of the slats, backing layers, and mounting depth |
| Resonant panel | The construction can be selected for operation in a specific frequency range |
Perforated surfaces and materials placed behind them should be evaluated together. Gustafs' Absorber Systems Description shows how perforation, rear cavity, and porous filling affect the final result.
Why Thickness is Important
A thin porous panel often works more effectively at medium and high frequencies. Increasing the thickness can improve absorption at lower frequencies, though the result also depends on other material properties.
Therefore, adding only thin panels to a room may reduce high-frequency reverberation while leaving low-frequency problems. In such an environment, the sound becomes less sharp, but a booming effect can still be heard.
GIK Acoustics' Explanation of Panel Thickness discusses this relationship with the effective frequency range. Comparing different materials based solely on thickness is insufficient — complete absorption data is required.
What an Air Layer Behind the Panel Changes
A porous panel mounted at a distance from a wall may have different absorption than one attached directly to the wall. An appropriate air layer can increase efficiency at certain frequencies.
This does not mean that an air layer will fully replace a thicker material in every case. The combined depth of the panel and the cavity, the construction, and the frequency range are significant.
The manufacturer's rating must relate to the same mounting specified in the project. The result of a system tested with a cavity and additional absorber cannot be attributed to a decorative panel mounted directly on a wall.
What NRC and αw Mean
NRC — Noise Reduction Coefficient is a single-number rating for absorption that summarizes results obtained at specified frequencies. It is related to the ASTM C423 method.
αw — The weighted sound absorption coefficient is determined by the ISO 11654 evaluation method. Absorption classes are also used in this system.
Ecophon's Explanation of Sound Absorption Classes describes the difference between these metrics.
NRC and αw are not the result of the same calculation, and direct substitution is incorrect. Both are useful for initial comparison, but they do not replace the frequency-dependent absorption table.
A high NRC does not mean that noise in a room will be reduced by that same percentage. The final result depends on the area of the panels, their placement, and the remaining surfaces in the room.
Where to Place Panels
The goal of placement should be to solve a specific acoustic problem. Excessive reverberation in a room, repetitive reflections between two parallel walls, and echo returning from the rear wall may require different solutions.
In a conference room, ceiling absorption often allows for the treatment of a large area. Wall panels may be needed to reduce remaining strong reflections.
Treating only the ceiling is not sufficient for all rooms. Problems between solid parallel walls may still remain.
In an auditorium, removing all reflections is not the goal: some early reflections help deliver useful sound to the listener. Therefore, the treatment of a large hall should be planned by considering sound propagation.
How Many Panels are Needed
Covering a certain percentage of the room's area with panels is not a universal rule. The required quantity depends on volume, existing absorption, furniture, the number of people, and desired reverberation.
Initial calculations can estimate the need for additional absorption in each frequency range. For spaces with complex geometry or high requirements, more detailed modeling and measurements may be needed.
When evaluating free-hanging elements, an equivalent absorption area for a single element is sometimes used. Such data should not be directly confused with the coefficient for a continuous ceiling.
Absorption vs. Sound Insulation
Acoustic panels reduce reflected sound inside a room. To reduce sound transmission to an adjacent room, it is necessary to evaluate the partition construction and all flanking paths.
Rockfon's Explanation of Sound Absorption and Insulation distinguishes these two tasks.
If sound is passing through door gaps, ventilation ducts, or a lightweight partition, adding panels to a wall will not fully solve the problem. A high absorption rating should not be used as a sound insulation characteristic.
What Data to Request When Purchasing
For technical assessment, the following are useful:
* Absorption test report and frequency results; * Full description of the tested construction; * Panel thickness, dimensions, and mounting depth; * Data on coverings and backing layers; * Documentation of reaction to fire appropriate for the project; * Instructions for brackets, maintenance, and cleaning.
Wood decor, fabric, or paint can change acoustic properties. Arbitrary repainting of the surface or covering with an unsuitable layer can close pores and openings.
Installation must be performed with the agreed-upon system. For example, Troldtekt's Installation Instructions define separate details for different constructions.
How to Evaluate the Result After Installation
During inspection, changes in reverberation, unwanted echo, and speech perception are evaluated in various locations. Initial and final measurements must be conducted under comparable conditions.
In a conference room, it is useful to test with microphones and a remote listener. This shows how the treated space affects the actual meeting sound.
Documentation for project handover should record the type, quantity, layout, and actual mounting construction of the panels. This will make it possible to link the result to the completed work and correctly plan further changes.
Sources
- https://www.usg.com/en-US/learning-reference/performance/acoustic/principles
- https://gustafs.com/knowledge-hub/room-acoustics/gustafs-sound-absorbers/
- https://www.gikacoustics.com/blogs/knowledge-base/how-thick-should-acoustic-panels-be
- https://www.ecophon.com/en/about-ecophon/acoustic-knowledge/how-to-create-good-room-acoustics/sound-absorption-classes/
- https://en.rockfon.international/resources/faq/sound-absorption-sound-insulation-difference
- https://www.troldtekt.com/web-tools-downloads/download-materials/installation-instructions/
Project Context
Ready to Apply This in Your Space?
A final engineering solution requires an assessment of your space, intended use and existing infrastructure.
Request a Consultation