Architectural Lighting
Lux and Lumens: What Is the Difference and Why Is It Important for Lighting and AV Systems?
The lumen describes luminous flux, lux describes surface illuminance, and nits describe screen luminance. Understanding the difference helps in properly planning lighting, projection, and video conferencing systems.
Lux and lumens are different units of measurement for light. Lumens describe luminous flux, while lux describes the luminous flux incident on a surface per unit area. Simply put, lumens answer the question of how much light a source emits, while lux shows how illuminated a specific surface is. Difference between Lux and Lumens — Waveform Lighting.
Knowing this difference is important not only when selecting lighting fixtures, but also when planning theatrical lighting, conference rooms, video filming, and projection systems.
What Is a Lumen?
The lumen, with the symbol lm, is the unit of luminous flux. It measures visible light by taking into account the spectral sensitivity of human vision, rather than just the electrical power of the source.
For example, the 2,000 lumens indicated in a light fixture's data describe its luminous flux. This number in itself does not show how much light will reach a table, a stage, or a person's face. To determine this, it is necessary to consider light distribution, distance, and the space. Photometric Quantities and Units — BIPM.
What Is a Lux?
Lux, with the symbol lx, is the unit of illuminance. One lux is equal to one lumen incident on one square meter:
1 lx = 1 lm/m²
Lux can be used to evaluate the illuminance of a desk, stage zone, projection screen, or the face of a video conference participant. The reading can vary at different points in the same room, even if the light fixtures are unchanged. Definition of Lux — BIPM.
How Is Lux Related to Lumens?
Average surface illuminance is calculated by dividing the luminous flux incident on it by the area:
Average Illuminance = Luminous flux incident on the surface ÷ Surface area
In a study example, if 1,000 lumens are distributed entirely and evenly over one square meter, the illuminance is 1,000 lux. When the same flux is distributed over ten square meters, the average illuminance will be 100 lux.
An important condition is that the flux used in the formula must fall precisely on the surface in question. Dividing the total lumens of a light fixture by the area of the room will not give an accurate result for real lighting: part of the light falls on other surfaces, while part is absorbed by optics and materials.
Why Might Light Fixtures with the Same Lumens Provide Different Illumination?
Two light fixtures might emit the same luminous flux, but one might cover a wide area, while the other concentrates light in a narrow beam. In the latter case, the illuminance at the center of the beam might be higher.
Therefore, a theatrical light fixture's data of “5,000 lux” is insufficient if we do not know the measurement distance, beam angle, and measurement point. Indicators to be compared with each other must describe identical conditions. Light Distribution and Measurement Distance — Waveform Lighting.
How Is the Topic Discussed in the CTS Guide?
The 3rd edition of the CTS Certified Technology Specialist Exam Guide discusses these issues in the video systems chapter. According to the book's printed pagination, pages 80–82 cover light units and the influence of distance, page 85 covers ambient lighting, and pages 116–117 cover the estimation of luminous flux for projection systems. Source: CTS Certified Technology Specialist Exam Guide, 3rd Edition.
An important addition in the guide is that it distinguishes between luminous flux, surface illuminance, and luminance.
| Quantity | Unit | Describes |
|---|---|---|
| Luminous flux | Lumen — lm | The amount of luminous flux |
| Illuminance | Lux — lx | Flux incident on a surface per unit area |
| Luminance | Candela per square meter — cd/m² | Light emitted or reflected from a surface in a specific direction |
The “nit,” which is common in screen specifications, is a unit of luminance: 1 nit = 1 cd/m². Therefore, 500 nits for a monitor and 500 lux for a workspace are different characteristics and are not directly comparable.
Distance and the Inverse Square Law
The CTS guide explains that as the distance from a source increases, light is distributed over a larger area. When approaching a point source, under conditions of constant direction and surface orientation, illuminance is inversely proportional to the square of the distance.
If, under such conditions, the illuminance at a distance of two meters is 800 lux, the expected figure at four meters will be 200 lux — four times less. This is a study example and not a guaranteed result for any given light fixture.
In a real space, factors such as the size of the fixture, optics, beam shape, and reflections from surfaces have an influence. Especially at close distances or in the case of complex optical systems, manufacturer photometric data or on-site measurement is required.
Lux and Lumens in Projection Systems
The CTS guide describes the nine-zone measurement method: a white image is displayed on the screen, the area is divided into nine equal parts, and the illuminance is measured at the center of each part. The resulting average figure is multiplied by the image area.
In a study example, if the average illuminance is 400 lux and the image area is five square meters, the estimated luminous flux will be:
400 lx × 5 m² = 2,000 lm
A single reading taken at the center of the screen is not enough to determine the total flux. It is also necessary to exclude or appropriately account for ambient light.
The method discussed in the guide should not be considered a full compliance test for any modern product. When comparing projectors, the specified measurement standard and operating mode should be checked. For example, in Epson documentation, the white light output is specified according to ISO 21118 and varies between normal and reduced output modes. Projector Measurement Conditions — Epson.
Why Doesn't More Lumens Solve All Image Problems?
According to CTS, ambient light reaching the screen reduces image contrast. Room lighting or light entering from a window can brighten dark areas and make it difficult to distinguish details.
Therefore, selecting a projector based on lumens alone is insufficient. It is also necessary to evaluate screen size, material, and ambient lighting. When distributing the same flux over a larger image, the average illuminance decreases. However, changing only the projector distance does not automatically mean the same reduction if the image size remains constant via optics.
Measurement in Conference and Stage Spaces
A lux meter measures illuminance at the location and with the orientation where its sensor is placed. Measuring on a desk describes the desk's lighting and not necessarily the lighting on a face directed toward a camera.
Given this difference, in a video conferencing space, it is useful to measure both the workspace and the plane of the participants' faces. On a stage, the evaluation should relate to the performer's actual location, the direction of the light fixture, and the lighting scenario used. This is a practical application of CTS measurement principles and not a single numerical standard for all spaces.
Conclusion
Lumens show luminous flux, lux shows the illuminance of a specific surface, and nits show the luminance of a screen or other surface. For planned lighting and AV system design, these figures must be evaluated together, considering measurement distance, direction, area, and environmental conditions.
Sources
- https://www.waveformlighting.com/home-residential/what-is-the-difference-between-lux-and-lumens
- https://www.bipm.org/documents/20126/41749107/Principles%2Bgoverning%2Bphotometry/8365350c-bf72-3cf2-bf03-324bf5c01b62
- https://files.support.epson.com/docid/cpd5/cpd59339/source/specifications/reference/pleb750f/spex_general_pleb750f.html
- CTS Certified Technology Specialist Exam Guide — 3rd Edition; pages 80–82, 85, and 116–117 (source referenced in the uploaded article)
Project Context
Ready to Apply This in Your Space?
A final engineering solution requires an assessment of your space, intended use and existing infrastructure.
Request a Consultation