DIALux vs. RELUX — What is the difference and when to use which?

DIALux evo and ReluxDesktop for lighting planning: space modeling, photometric calculations, CAD/BIM and IFC import, evaluation of results, luminaire data, and licenses.

2026-10-15

DIALux evo and ReluxDesktop are programs for lighting planning and calculation. They allow for space modeling, the placement of real luminaires, and the evaluation of light distribution before equipment installation.

Both programs are used to study artificial and natural lighting, compare design solutions, and prepare technical reports. The choice depends on the project type, the initial model, required functions, and the professional's workflow.

What a lighting program helps to calculate

Determining the number of luminaires based solely on room area and power is insufficient. The result is affected by ceiling height, optics, mounting location, surface reflectance properties, and obstacles in the space.

A model of these conditions is created in the lighting program. The calculation allows for the evaluation of:

- Illuminance on the work surface, floor, or wall; - Uniformity of light distribution; - Under-lit or over-lit areas; - Discomfort glare evaluated by the appropriate method; - The effect of different luminaires and layouts on the result.

The software is a tool for calculation and comparison. The professional defines the design criteria and the acceptability of the results.

DIALux evo — A unified model of space and lighting

DIALux evo allows for the processing of individual rooms, multiple building spaces, and outdoor areas. It is possible to combine geometry, materials, luminaires, and calculation surfaces in the project.

The workflow includes creating or importing a space, placing lighting, calculating, and preparing documentation. Three-dimensional views and the graphical representation of results facilitate both the technical evaluation of the decision and discussion with the client.

DIALux evo can be convenient for projects where managing several spaces in one model and comparing different lighting scenarios are required. The program also includes features for planning daylight and emergency lighting.

ReluxDesktop — Lighting calculation and CAD/BIM workflow

ReluxDesktop is intended for planning artificial lighting, daylight, and sensors. It allows for space modeling, luminaire placement, defining calculation areas, and creating reports.

Specialized add-ons are also available within the RELUX ecosystem. Therefore, when evaluating a specific task, it is important to distinguish between the main program functions and the capabilities obtained through additional modules.

For teams working in Revit, ReluxCAD for Revit is worth noting, which serves to exchange data between the architectural model and lighting planning. Such a connection is particularly useful when architectural and engineering changes occur regularly in the project.

Using an architectural model

A significant issue when working with either program is the transfer of the initial drawing or 3D model.

A 2D CAD plan can be used to construct the space. In the case of a BIM model, importing geometry and relevant data is possible, which reduces the volume of manual modeling.

The RELUX IFC import manual describes working with the open BIM format. DIALux evo also has IFC data exchange capabilities, though the availability of relevant features should be checked according to the license.

When transferring from Archicad or another BIM program, it is advisable to prepare the model in advance: keep only the spaces, openings, and significant obstacles necessary for lighting calculation. Excessive detailing can complicate the workflow.

After import, check the scale, room heights, surfaces, and openings. A successfully opened file does not necessarily mean the model is fully optimized for calculation.

Which program is more accurate?

Accuracy cannot be defined by the program's name. For reliable results, correct input data and parameters appropriate for the specific task are required.

The calculation is affected by:

- Photometric data of the luminaire and chosen optics; - Mounting height and aiming; - Surface reflectance coefficients; - Layout of the calculation surface and grid; - Maintenance factor; - Geometry and light-obstructing objects.

If a wall is described as a light surface in one program and dark in another, a different result is expected. To compare programs, identical conditions must first be created.

The maintenance factor must also be chosen with justification: it accounts for the reduction of luminous flux and the impact of dirt accumulation over time.

Rendering and lighting calculation

A 3D image is useful for understanding the concept of space and lighting. However, the brightness shown on the screen depends on image processing and monitor settings.

Technical evaluation requires the use of calculated values, isoluxes, false-color maps, and reports. On a false-color map, the color represents a specific range and not the actual color of the surface.

For example, a red area might simply indicate the upper range of the chosen scale. Its value should be evaluated according to the scale and project requirements.

Luminaire data and licenses

When choosing a program, it should be checked in advance whether the required manufacturer's products and the rights to use them are available.

Per DIALux licensing terms, basic functionality is free to use with luminaires from partner manufacturers. For products from other manufacturers, an Unlock Non-Members or relevant Pro subscription is provided. Some advanced import and export functions are also linked to the Pro package.

In RELUX, planning with products from partner manufacturers is free, while the ReluxThirdParty license is used for calculating products from non-partner manufacturers.

Consequently, along with the existence of a photometric file, its licensing terms for use must also be checked.

When to choose which?

Project NeedIssue to verify when choosing
Lighting for an office, shop, or exhibition spaceIn which program is the required model created and verified more conveniently
Teamwork based on RevitCapabilities of the RELUX Revit add-in and project exchange requirements
Transferring IFC model from ArchicadImport quality, room recognition, and appropriate license
Comparing luminaires from different manufacturersAvailability of photometric data and terms of use
Sports or other specialized facilityRequired calculation methods, reports, and additional modules
Preparing a report for the clientDocumentation composition, formatting, and export formats

How to verify the choice in practice

For evaluation, it is useful to complete one small pilot project in both programs. With identical geometry, luminaires, and calculation conditions, it will become clear how easy it is to prepare the model, make changes, and receive a report.

When choosing, the team's experience should also be considered. A well-mastered program and an established workflow reduce data entry errors and simplify project verification.

Reliability of the final result is ensured by a properly prepared model, justified parameters, and on-site measurements conducted after installation.