AV Control
Stadium Design According to FIFA and UEFA Requirements
Defining stadium category and competition requirements, lighting calculations, sound reinforcement, broadcast infrastructure, backup power and demonstrating compliance.
Stadium design according to FIFA and UEFA requirements means coordinating sporting, architectural and engineering decisions with the competitions the venue is intended to host.
This process covers the field, spectator seating, safety, accessibility, lighting, sound reinforcement and broadcast infrastructure. The quality of an individual system does not establish compliance of the entire stadium: requirements must be met and checked collectively.
The first step is to identify the target events and the relevant documents.
What Do “FIFA and UEFA Standards” Mean?
This term often refers to several different documents: infrastructure regulations, technical guidelines and the requirements of a particular competition.
FIFA Stadium Guidelines provide a broad framework for stadium planning, construction and operation. FIFA itself notes that a single, exhaustive set of requirements cannot be applied to every stadium.
UEFA Stadium Infrastructure Regulations establish infrastructure criteria for stadium categories.
Documents should distinguish mandatory conditions, recommendations and requirements that depend on a particular event.
The Project Basis: Stadium Category and Competition
UEFA's infrastructure regulations distinguish stadium categories from category one to category four. Higher categories involve broader and stricter criteria.
However, naming a category alone is insufficient. A particular competition's regulations may establish additional requirements or modify general provisions. This principle is explained in the scope of UEFA's regulations.
The design brief should ideally record:
- Which competitions the stadium is intended to host; - Which infrastructure category is required; - What level of television broadcasting must be possible; - Which edition of which document applies; - What future expansion is planned.
Lighting Level and Stadium Category Are Different Concepts
UEFA stadium categories and the levels used in the lighting guide are not automatically the same. FIFA lighting classes also have their own purpose.
A requirement for “category four lighting” may therefore be incomplete unless it identifies the relevant regulations, competition and target criteria.
UEFA's explanation of lighting level selection requires the project to be linked to the planned competition and future use.
Field Lighting Is Not Assessed by Lux Alone
Average illuminance is an important measure, but it does not describe the whole picture.
The project considers:
| Parameter | What It Assesses |
|---|---|
| Horizontal illuminance | Light reaching the field surface |
| Vertical illuminance | Illumination of players from different camera directions |
| Uniformity | Light distribution and differences between areas |
| Glare discomfort | The effect of luminaires on players' and other observers' vision |
| Color rendering | Perception of colors under the lighting |
| Temporal light modulation | Potential flicker and banding on camera |
FIFA's technical systems guide connects lighting with the needs of players, spectators and broadcasters.
Exact values are selected from the relevant requirements table. Achieving one parameter alone does not mean the remaining conditions have been met.
Photometric Calculation and Luminaire Placement
Calculations require the actual geometry of the field, spectator seating, roof and masts. The luminaire model is used together with photometric data for the relevant optics and aiming directions.
The report should show the calculation grid, planes, heights and assumptions used. This allows another specialist to check the result.
The decline in luminous flux over time must also be considered. UEFA's explanation of the maintenance factor relates this to dirt, aging and documented maintenance.
A computer model predicts the design result. The installed system's actual performance is measured on site.
Sound Reinforcement and Announcements
The stadium audio system should deliver announcements to the relevant areas. Loudspeaker selection considers coverage, background noise, reflections and signal time alignment.
UEFA's public address requirement provides for messages to be delivered throughout the stadium and for a backup power supply.
The design specification should additionally define measurable audio criteria and the conditions for checking them. Any specific speech intelligibility threshold must be based on a document applicable to the project: arbitrarily declaring it a “universal UEFA requirement” is incorrect.
Emergency announcement functionality is planned in coordination with the safety design.
Broadcast Infrastructure
A camera position is more than a point at which to place equipment. It needs operator space, an unobstructed view, access and a safe cable route.
FIFA's media and broadcast guide considers camera positions, interview areas, commentators and the area for outside broadcast facilities.
Camera placement should also be coordinated with lighting design. Vertical illuminance assessment is meaningful when it considers the directions from which filming is planned.
Providing infrastructure and permanently purchasing every camera are separate decisions. Their scope is determined in agreement with the event organizer and broadcaster.
Power and Emergency Operating Modes
Field lighting, evacuation lighting and the announcement system perform different functions. Main and backup power supplies must be defined separately for each.
UEFA's floodlighting provisions include backup power conditions and testing.
The project describes what happens when power is lost, how long switchover takes and which functions continue. The presence of a generator or UPS is not sufficient evidence unless the complete scenario has been tested.
How Is Compliance Demonstrated?
A requirements compliance matrix is a practical tool. Each item should be linked to a source, a design solution and a verification method.
The final package may include calculations, working drawings, equipment data, measurement reports and tests of backup modes.
The responsibilities of the national association and UEFA within UEFA's process are described in the article on roles and responsibilities. The designer's report is therefore important, but it does not replace the applicable inspection and decision procedure.
Sources
- https://football-technology.fifa.com/innovation/stadium-guidelines
- https://documents.uefa.com/r/Technical-Regulations/UEFA-Stadium-Infrastructure-Regulations-Online
- https://documents.uefa.com/r/PxVtjcYr9Ntgwd0wYgq2xw/WOFVr3Qth1qPkb5nkGEGag
- https://documents.uefa.com/r/UEFA-Stadium-Lighting-Guide-2023-2023/UEFA-illuminance-levels-Online
- https://ipt.fifa.com/innovation/stadium-guidelines/technical-guidelines/stadiums-guidelines/technical-systems-and-services
- https://documents.uefa.com/r/UEFA-Stadium-Lighting-Guide-2023-2023/Maintenance-factor-Online
- https://documents.uefa.com/r/PxVtjcYr9Ntgwd0wYgq2xw/YQkvCJlducYVpY9159CGhw
- https://publications.fifa.com/de/football-stadiums-guidelines/technical-guideline/main-user-groups/media-and-broadcast/
- https://documents.uefa.com/r/PxVtjcYr9Ntgwd0wYgq2xw/P1QRtOar3QJL_XQWZllUsg
- https://documents.uefa.com/r/PxVtjcYr9Ntgwd0wYgq2xw/yjMxFiszvH6oOfPcIbZpuQ
Project Context
Ready to Apply This in Your Space?
A final engineering solution requires an assessment of your space, intended use and existing infrastructure.
Request a Consultation